Abstract :
Worst case analysis (WCA) assignments are often considered to be daunting tasks, with a comprehensive analysis for a power converter often being 500 pages long. In this paper, the authors intend to show how to apply common analytical techniques for power supply designs, rather than presenting new or exotic analysis methods or models. Presented are tutorial guidelines to streamline that process, showing procedures and techniques to perform a WCA that will not only fulfill requirements, but also help find most hidden design problems
Keywords :
design engineering; power convertors; power supplies to apparatus; WCA; performance guidelines; power converter; power supply designs; tutorial guidelines; worst case analysis assignments; Computer aided software engineering; Guidelines; Information analysis; Magnetic analysis; Maintenance engineering; Monte Carlo methods; Performance analysis; Power engineering and energy; Power supplies; Voltage control;