Title :
Applications of half-turn on E-core in switching power supplies
Author :
Xingsheng Zhou ; Chen, Dan ; Jamerson, Clifford
Author_Institution :
Bradley Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
Abstract :
A turn around an outside leg of an E-core is called a half-turn because it encloses only one-half of the cross-sectional area of a turn around the center leg. It is well known that a half-turn in a secondary winding of a power transformer greatly increases the leakage inductance between windings, thus causing an adverse effect on cross-regulation. However, the increased leakage inductance of a half-turn can be very beneficial in tapped inductors for boost circuits and in coupled output chokes. This paper explains some of these little-known applications of a half-turn. The theory and formulae for prediction of leakage inductance added by such a half-turn are presented
Keywords :
inductance; magnetic cores; magnetic leakage; power supply circuits; switched mode power supplies; switching circuits; windings; E-core; applications; boost circuits; coupled output chokes; cross-regulation; half-turn; leakage inductance; power transformer; secondary winding; switching power supplies; tapped inductors; Coupling circuits; Ferrites; Filters; Inductance; Inductors; Leg; Magnetics; Power engineering and energy; Power supplies; Power transformers;
Conference_Titel :
Applied Power Electronics Conference and Exposition, 1999. APEC '99. Fourteenth Annual
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-5160-6
DOI :
10.1109/APEC.1999.750522