  • Abstract
    A turn around an outside leg of an E-core is called a half-turn because it encloses only one-half of the cross-sectional area of a turn around the center leg. It is well known that a half-turn in a secondary winding of a power transformer greatly increases the leakage inductance between windings, thus causing an adverse effect on cross-regulation. However, the increased leakage inductance of a half-turn can be very beneficial in tapped inductors for boost circuits and in coupled output chokes. This paper explains some of these little-known applications of a half-turn. The theory and formulae for prediction of leakage inductance added by such a half-turn are presented
  • Keywords
    inductance; magnetic cores; magnetic leakage; power supply circuits; switched mode power supplies; switching circuits; windings; E-core; applications; boost circuits; coupled output chokes; cross-regulation; half-turn; leakage inductance; power transformer; secondary winding; switching power supplies; tapped inductors; Coupling circuits; Ferrites; Filters; Inductance; Inductors; Leg; Magnetics; Power engineering and energy; Power supplies; Power transformers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 1999. APEC '99. Fourteenth Annual
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-5160-6
  • Type

    conf

  • DOI
    10.1109/APEC.1999.750522
  • Filename
    750522