DocumentCode
2626233
Title
A low power front-end prototype for silicon pixel detectors with 100ps time resolution
Author
Martoiu, Sorin ; Rivetti, Angelo ; Mazza, Gianni ; Osmic, Fadmar ; Marchetto, Flavio
Author_Institution
National Institute of Nuclear Physics (INFN), Torino, Italy
fYear
2008
fDate
19-25 Oct. 2008
Firstpage
2958
Lastpage
2961
Abstract
A time-accurate front-end prototype for silicon pixel particle detectors is presented. The circuit has been designed to meet the requirements of the NA62’s beam spectrometer, the Gigatracker. It consists of a charge-sensitive preamplifier (CSP) and a fully integrated constant-fraction discriminator (CFD), showing less than 80ps jitter (rms) for one MIP signal and less than 250ps peak-to-peak time-walk for 0.5 to 5 MIP signal range. The overall time resolution is 100ps rms, accounting for the Landau distribution of the detector signal, while the total power consumption is 600 uW. The circuit was implemented in a 0.13 um CMOS commercial process, occupying 280μm × 80μm of silicon space.
Keywords
Circuits; Computational fluid dynamics; Jitter; Preamplifiers; Prototypes; Radiation detectors; Signal detection; Signal resolution; Silicon; Spectroscopy;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location
Dresden, Germany
ISSN
1095-7863
Print_ISBN
978-1-4244-2714-7
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2008.4774984
Filename
4774984
Link To Document