DocumentCode :
2627089
Title :
A portable readout system for microstrip silicon sensors (ALIBAVA)
Author :
Marco-Hernandez, Ricardo
Author_Institution :
IFIC (CSIC-Universidad de Valencia), Paterna, 46980 Spain
fYear :
2008
fDate :
19-25 Oct. 2008
Firstpage :
3201
Lastpage :
3208
Abstract :
A readout system for microstrip silicon sensors has been developed as a result of a collaboration among the University of Liverpool, the CNM (Centro Nacional de Microelectrónica) of Barcelona and the IFIC (Instituto de Física Corpuscular) of Valencia. The name of this collaboration is ALIBAVA and it is integrated in the RD50 Collaboration. This system is able to measure the collected charge in one or two microstrip silicon sensors by reading out all the channels of the sensor(s), up to 256, as an analogue measurement. The system uses two Beetle chips to read out the detector(s). The Beetle chip is an analogue pipelined readout chip used in the LHCb experiment. The system can operate either with non-irradiated and irradiated sensors as well as with n-type and p-type microstrip silicon sensors. Heavily irradiated sensors will be used at the SLHC, so this system can be used to research the performance of microstrip silicon sensors in conditions as similar as possible to the SLHC operating conditions. The system has two main parts: a hardware part and a software part. The hardware part acquires the sensor signals either from external trigger inputs, in case of a radioactive source setup is used, or from a synchronised trigger output generated by the system, if a laser setup is used. This acquired data is sent by USB to be stored in a PC for a further processing. The hardware is a dual board based system. The daughterboard is a small board intended for containing two Beetle readout chips as well as fan-ins and detector support to interface the sensors. The motherboard is intended to process the data, to control the whole hardware and to communicate with the software by USB. The software controls the system and processes the data acquired from the sensors in order to store it in an adequate format file. The main characteristics of the system will be described. Results of measurements acquired with n-type and p-type non-irradiated detectors using both the l- - aser and the radioactive source setup will be also presented and discussed.
Keywords :
Charge measurement; Collaboration; Current measurement; Detectors; Hardware; Microstrip; Semiconductor device measurement; Sensor systems; Silicon; Universal Serial Bus;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location :
Dresden, Germany
ISSN :
1095-7863
Print_ISBN :
978-1-4244-2714-7
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2008.4775030
Filename :
4775030
Link To Document :