• DocumentCode
    2629442
  • Title

    Voltage and frequency controller for a stand alone PV system with battery storage element

  • Author

    Chikh, A. ; Chandra, A.

  • Author_Institution
    Dept. of Electr. Eng., Ecole de Technol. Super., Montréal, ON, Canada
  • fYear
    2012
  • fDate
    25-28 Oct. 2012
  • Firstpage
    1172
  • Lastpage
    1177
  • Abstract
    In this paper, we present an efficient voltage and frequency controller for a stand-alone photovoltaic (PV) system with a battery storage element. A maximum power point technique (MPPT) is used to extract the maximum power available in the PV array despite the weather conditions variations. The array output voltage is converted to an AC voltage using a PWM voltage source inverter where its output voltage and frequency are regulated using a closed loop control which is feed to a stand-alone load. Moreover, the battery storage elements are used to compensate for any variation in climatic conditions or load profile. The results show the effectiveness of the proposed MPP technique and the developed voltage/frequency controller.
  • Keywords
    PWM invertors; battery storage plants; frequency control; maximum power point trackers; photovoltaic power systems; voltage regulators; MPPT; PV array; PWM voltage source inverter; battery storage element; battery storage elements; closed loop control; frequency controller; load profile; maximum power extraction; maximum power point technique; maximum power point tracking; stand alone PV system; voltage controller; weather conditions; Frequency control; Lead; Nonlinear optics; Optical arrays; Optical control; Optical frequency conversion; Maximum power point tracking (mppt); junction current; optimal conductance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
  • Conference_Location
    Montreal, QC
  • ISSN
    1553-572X
  • Print_ISBN
    978-1-4673-2419-9
  • Electronic_ISBN
    1553-572X
  • Type

    conf

  • DOI
    10.1109/IECON.2012.6388605
  • Filename
    6388605