• DocumentCode
    2629836
  • Title

    Experimental measurements for the SiliPET project: A small animal PET scanner based on stacks of silicon detectors

  • Author

    Auricchio, N. ; Di Domenico, G. ; Milano, L. ; Malaguti, R. ; Ambrosi, G. ; Ionica, M. ; Fiandrini, E. ; Zorzi, N. ; Boscardin, M. ; Zavattini, G.

  • Author_Institution
    Department of Physics, University of Ferrara, Italy
  • fYear
    2008
  • fDate
    19-25 Oct. 2008
  • Firstpage
    366
  • Lastpage
    369
  • Abstract
    In this paper we propose a new scanner for small-animal positron emission tomography (PET) based on stacks of double sided silicon detectors. Each stack is composed of 40 planar detectors with dimension 60 × 60 × 1 mm3 and 128 orthogonal strips on both sides to read the two coordinates of interaction, the third being the detector number in the stack. Multiple interactions in a stack are discarded. In this way we achieve a precise determination of the interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results were obtained with MEGA prototype tracker (11 double sided Si detector layers, each with a thickness of 0.5 mm and a strip pitch of 470 microns), divided into two stacks 2 cm apart made of respectively 5 and 6 prototype layers, placing a small spherical 22Na source in different positions. We report on the results, spatial resolution, spectral and timing performances obtained with double sided silicon detectors, manufactured by ITC-FBK, having an active area of 3 x 3 cm2 and a strip pitch of 500 mm. Two different strip widths of 300 μm and 200 μm, and two thicknesses of 1 mm and 1.5 mm, equipped with 64 orthogonal p and n strips on opposite sides were read out with the VATAGP2.5 ASIC, a 128-channel “general purpose” charge sensitive amplifier. Each channel is composed of a low-noise/ low-power preamplifier, a shaper (peaking time of 3.1 μs) with sample/hold, multiplexed analogue readout and a fast shaper (peaking time of 1.1 μs) that gives a trigger signal.
  • Keywords
    Animals; Detectors; Manufacturing; Positron emission tomography; Prototypes; Silicon; Solids; Spatial resolution; Strips; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
  • Conference_Location
    Dresden, Germany
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-2714-7
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2008.4775187
  • Filename
    4775187