DocumentCode
2629922
Title
Development of high accuracy measurement system for dissipation current of nonpolar polymers
Author
Tohyama, K. ; Nagao, M. ; Tokoro, T. ; Kosaki, M.
Author_Institution
Numazu Coll. of Technol., Japan
Volume
2
fYear
2000
fDate
2000
Firstpage
713
Abstract
In order to clarify the high field dielectric properties, high accuracy measurement system for dissipation current of nonpolar polymers without Capacitance Bridge was developed. In high temperature and high field region, it is known that the dissipation current is getting large due to charge injection from the electrode. Furthermore the shapes of dissipation current waveform deviate from sinusoidal waveform and it shows nonlinear property. Therefore, it is important to measure the dissipation current with high accuracy, which include harmonics of dissipation current and to investigate the space charge effect under ac field. In this paper, we will discuss the technique, which enables the observation of the high field dissipation current under ac high field
Keywords
dielectric measurement; electric current measurement; organic insulating materials; polymers; space charge; AC high field dielectric properties; charge injection; dissipation current; electrical insulation; high temperature characteristics; measurement system; nonlinear harmonics; nonpolar polymer; space charge; Bridge circuits; Capacitance measurement; Charge measurement; Current measurement; Dielectric measurements; Electrodes; Polymers; Shape; Space charge; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2000 Annual Report Conference on
Conference_Location
Victoria, BC
Print_ISBN
0-7803-6413-9
Type
conf
DOI
10.1109/CEIDP.2000.884057
Filename
884057