• DocumentCode
    2629939
  • Title

    Clamping voltage control strategy for the Actively Clamped Resonant DC-link inverter

  • Author

    Chen, Qinye ; Zhang, Dehua ; Hou, Yaojie ; Jin, Lixiang

  • Author_Institution
    Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China
  • fYear
    2012
  • fDate
    25-28 Oct. 2012
  • Firstpage
    287
  • Lastpage
    292
  • Abstract
    The efficiency and life expectancy of PV grid-tie micro-inverter is of critical effect to its performance. The Actively Clamped Resonant DC-link Inverter has remarkable features of simple structure and high efficiency with only one auxiliary switch. The short-circuit control is the traditional clamp circuit control strategy. But the short-circuit process increases the DC-link losses and the control complexity. A no short-circuit control strategy is presented to overcome the above problems. The calculation results show that no short-circuit control strategy reduces the loss of inverter. Film capacitor is chosen to be the clamp capacitor.
  • Keywords
    capacitors; clamps; invertors; short-circuit currents; voltage control; PV grid-tie microinverter; actively clamped resonant DC-link inverter; clamp capacitor; clamp circuit control; clamping voltage control; control complexity; film capacitor; short-circuit control; Actively clamped resonant dc-link inverter; Loss calculation; Micro-inverter; No short-circuit control strategy; Two-amplitude control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
  • Conference_Location
    Montreal, QC
  • ISSN
    1553-572X
  • Print_ISBN
    978-1-4673-2419-9
  • Electronic_ISBN
    1553-572X
  • Type

    conf

  • DOI
    10.1109/IECON.2012.6388632
  • Filename
    6388632