Title :
Improved active clamp for secondary circuits
Author :
Sheehy, R. ; Dekter, J. ; Machin, N.
Author_Institution :
Rectifier Technol., Burwood, Vic., Australia
Abstract :
The paper describes improvements to an active clamp for secondary circuits in isolated converter topologies. The active clamp provides both voltage clamping of the secondary diodes and the recycling of diode reverse recovery energy stored in the leakage inductance of the transformer secondary winding. An isolated winding on the recycling circuit permits variation in the location of the output choke, which is shown to provide a possible 10 dB reduction of common mode noise. Results from a 700 W telecommunications rectifier using a planar transformer are presented
Keywords :
AC-DC power convertors; magnetic leakage; power transformers; rectifying circuits; telecommunication power supplies; transformer windings; 700 W; active clamp improvement; common mode noise reduction; diode reverse recovery energy recycling; isolated power converter topologies; leakage inductance; output choke location; planar transformer; secondary circuits; secondary diodes; telecommunications rectifier; transformer secondary winding; voltage clamping; Circuits; Clamps; Diodes; Inductance; Inductors; Rectifiers; Recycling; Switches; Switching converters; Voltage;
Conference_Titel :
Telecommunications Energy Conference, 2000. INTELEC. Twenty-second International
Conference_Location :
Phoenix, AZ
Print_ISBN :
0-7803-6407-4
DOI :
10.1109/INTLEC.2000.884240