DocumentCode
2632807
Title
Experimental results of the new ZVS PWM voltage source inverter with active voltage clamping and comparison with classical structures
Author
Péres, Adriano ; Barbi, Ivo
Author_Institution
Dept. of Electr. Eng., Regional Univ. of Blumenau, Brazil
fYear
2000
fDate
2000
Firstpage
173
Lastpage
179
Abstract
In this work, experimental results of the new pulsewidth-modulation zero-voltage-switching voltage source inverter is presented. At rated load, commutation under ZVS condition is satisfied, and a quasi ZVS commutation is guaranteed under all other load current. The novel topology has the feature of being modulated by any conventional pulse-width-modulation strategy employed in the hard-switching inverters. The maximum voltage applied in all switches is clamped and limited in a reduced value and it does not produce excessive current stress. Operation description, theoretical analysis and design example are presented in the paper. A comparison among the results obtained from the new inverter topology with classical structures is made, Including the results obtained from an Undeland snubber aided inverter
Keywords
DC-AC power convertors; PWM invertors; commutation; switching circuits; Undeland snubber aided inverter; VSI; ZVS PWM voltage source inverter; active voltage clamping; commutation; hard-switching inverters; inverter topology; pulse-width-modulation strategy; Circuit topology; Clamps; Pulse inverters; Pulse modulation; Pulse width modulation inverters; Resonance; Snubbers; Stress; Switches; Zero voltage switching;
fLanguage
English
Publisher
ieee
Conference_Titel
Telecommunications Energy Conference, 2000. INTELEC. Twenty-second International
Conference_Location
Phoenix, AZ
Print_ISBN
0-7803-6407-4
Type
conf
DOI
10.1109/INTLEC.2000.884247
Filename
884247
Link To Document