DocumentCode
2635676
Title
Once in ten thousand years [railway signalling systems]
Author
Bailey, D.F.
fYear
1995
fDate
27-30 Mar 1995
Firstpage
158
Lastpage
160
Abstract
The author discusses fail safe railway signalling systems and their failure. The investigation of `wrong side´ signalling failures is discussed. Examples of reliability and wrong side failure investigations are given. The failures covered include silver and copper ions migration in contacts, solid state interlocking (SSI) problems, and interference from traction systems and track circuits
fLanguage
English
Publisher
iet
Conference_Titel
Electric Railways in a United Europe, 1995., International Conference on
Conference_Location
Amsterdam
Print_ISBN
0-85296-631-8
Type
conf
DOI
10.1049/cp:19950198
Filename
396029
Link To Document