• DocumentCode
    2637016
  • Title

    Diagnosis of a Continous Stirred Tank Reactor Using Kalman Filter

  • Author

    Hsoumi, Aicha ; Harabi, Rafika El ; Ali, Saloua Bel Hadj ; Abdelkrim, Mohamed Naceur

  • Author_Institution
    Unite de Rech. Modelisation, Anal. et Commande des Syst. (MACS), ENIG, Tunisia
  • fYear
    2009
  • fDate
    7-9 Sept. 2009
  • Firstpage
    153
  • Lastpage
    158
  • Abstract
    This paper is dedicated to complex system diagnosis. Therefore, a Kalman filter has been proposed to cope with external disturbances and unpredictable faults that are associated with chemical processes. The continuous stirred tank reactor (CSTR) model with parametric uncertainties is linearized around a chosen steady state and discretized to apply the diagnosis approach. A Kalman filter is employed to generate conversion estimate for the CSTR using only temperature measurements and precedent estimates. Numerical simulation Results of a no isothermal CSTR with coolant jacket dynamics are presented. Robustness with respect to interpolation errors, disturbances and model parametric uncertainties is achieved by using the obtained Kalman filter.
  • Keywords
    Kalman filters; chemical reactors; coolants; fault diagnosis; interpolation; linearisation techniques; robust control; state estimation; temperature measurement; CSTR; Kalman filter; chemical processes; complex system diagnosis; continuous stirred tank reactor; coolant jacket dynamics; interpolation errors; model parametric uncertainties; parametric uncertainties; temperature measurements; Chemical processes; Continuous-stirred tank reactor; Coolants; Inductors; Interpolation; Isothermal processes; Numerical simulation; Robustness; Steady-state; Temperature measurement; Actuator and sensor faults; CSTR; Fault Detection and Isolation; Kalman filter; Model Parametric Uncertainties;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computational Intelligence, Modelling and Simulation, 2009. CSSim '09. International Conference on
  • Conference_Location
    Brno
  • Print_ISBN
    978-1-4244-5200-2
  • Electronic_ISBN
    978-0-7695-3795-5
  • Type

    conf

  • DOI
    10.1109/CSSim.2009.22
  • Filename
    5350166