DocumentCode
2637025
Title
Model-based validation of drive control firmware using Simulink
Author
Hinchley, D.A. ; Roberts, G.J. ; Loukadakis, G. ; Loukadakis, S. ; Parkes, A.W.
fYear
2012
fDate
27-29 March 2012
Firstpage
1
Lastpage
5
Abstract
This paper examines the use of Simulink to validate drive control firmware. Simulations are compared with measurements taken on a prototype 2 MW 3-level NPC converter. Simulink is used to validate a network bridge pulse-width-modulation (PWM) generator block.
Keywords
control engineering computing; electric drives; electric machine analysis computing; firmware; machine control; Simulink model-based validation; drive control firmware validation; network bridge PWM generator block; network bridge pulse-width-modulation generator block; power 2 MW; prototype 3-level NPC converter; Drive Control; Firmware; Simulink; Validation;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives (PEMD 2012), 6th IET International Conference on
Conference_Location
Bristol
Electronic_ISBN
978-1-84919-616-1
Type
conf
DOI
10.1049/cp.2012.0181
Filename
6242030
Link To Document