DocumentCode
2637456
Title
Series resonant high-voltage PFM DC-DC converter with voltage multiplier based a two-step frequency switching control for medical-use X ray power generator
Author
Sun, Junming ; Konishi, Hitoshi ; Ogino, Yoshio ; Chu, Enhui ; Nakaoka, Mutsuo
Author_Institution
Kyoto Denkiki Co. Ltd., Japan
Volume
2
fYear
2000
fDate
2000
Firstpage
596
Abstract
In general, high-voltage DC power supplies employing a variety of high-frequency inverters are implemented for constant value control schemes. In particular, their good transient and steady-state performances can not be achieved under wide load variations for a medical-use high voltage X ray generator ranging from 20 kV to 150 kV in the output voltage and from 0.5 mA to 1250 mA, respectively. A high-voltage DC power supply designed for X ray power generator applications is considered, which uses series resonant inverter-linked multistage DC voltage multiplier instead of conventional high voltage diode module rectifier connected to the secondary-side of a high-voltage transformer. A constant on-time/variable frequency control scheme of this converter operating at zero-current soft switching mode is described. Introducing the capacitor-diode cascaded multistage voltage multiplier, the secondary turn numbers, and secondary-side stray capacitance of the high-voltage high-frequency transformer as well as the rectifier diode voltage ratings can be greatly reduced. It is proven that the proposed converter control scheme of the 2 step changed frequency selection switching is more effective for improving output voltage responses. A series resonant high-frequency transformer-linked voltage-multiplying rectifier is evaluated for an X ray high voltage generator on the basis of simulation analysis and observed data in experiment
Keywords
DC-DC power convertors; X-ray production; capacitance; frequency control; high-frequency transformers; invertors; power supplies to apparatus; pulse frequency modulation; resonant power convertors; switching circuits; voltage control; voltage multipliers; 0.5 to 1250 mA; 20 to 150 kV; X ray high voltage generator; capacitor-diode cascaded multistage voltage multiplier; constant on-time/variable frequency control; constant value control schemes; high-frequency inverters; high-voltage DC power supply; high-voltage high-frequency transformer; medical-use X ray power generator; output voltage responses; rectifier diode voltage ratings; secondary turn numbers; secondary-side stray capacitance; series resonant high-voltage PFM DC-DC converter; series resonant inverter-linked multistage DC voltage multiplier; simulation analysis; steady-state performances; transient performances; two-step frequency switching control; voltage multiplier; zero-current soft switching; DC-DC power converters; Diodes; Load management; Power supplies; Rectifiers; Resonance; Resonant inverters; Steady-state; Switching converters; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Motion Control Conference, 2000. Proceedings. IPEMC 2000. The Third International
Conference_Location
Beijing
Print_ISBN
7-80003-464-X
Type
conf
DOI
10.1109/IPEMC.2000.884558
Filename
884558
Link To Document