DocumentCode
2637982
Title
Matrix converter clamp current reconstruction for fault detection
Author
Brunson, Christopher ; de Lillo, L. ; Empringham, L. ; Wheeler, Pat ; Clare, Jon
Author_Institution
Sch. of Electr. & Electron. Eng., Univ. of Nottingham, Nottingham, UK
fYear
2012
fDate
27-29 March 2012
Firstpage
1
Lastpage
6
Abstract
Matrix converters offer advantages over traditional AC-AC conversion technologies in high temperature environments; however in system critical applications were operation is paramount, it is desirable for the converter to continue operation under fault conditions, albeit with degraded performance. There have been several works in literature on the subject of fault tolerant matrix converters however all of these methods require a method of fault localisation for continued operation in the fault condition. It is also desirable for the fault detection and localisation scheme to use existing sensors to minimise cost. This paper describes a method of fault detection and localisation using only the existing sensors used in the operation of the converter and information know by the converters modulator.
Keywords
AC-AC power convertors; clamps; fault location; matrix convertors; AC-AC converter; clamp current reconstruction; converter modulator; fault detection; fault location; fault tolerance; matrix converter; Matrix converter; fault detection;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives (PEMD 2012), 6th IET International Conference on
Conference_Location
Bristol
Electronic_ISBN
978-1-84919-616-1
Type
conf
DOI
10.1049/cp.2012.0230
Filename
6242080
Link To Document