Title :
Design of automated medical diagnosis system with normal degree
Author :
Hata, Yutaka ; Ishikawa, Osamu ; Kondo, Katsuya ; Kobashi, Syoji
Author_Institution :
Graduate Sch. of Eng., Hyogo Univ., Himeji, Japan
Abstract :
This paper describes a design method of automated medical diagnosis system (AMDS), which provides a normal degree for a disease. In this paper, we consider blood test data of human. Suppose a disease which can be diagnosed by the test, first, we do statistical analysis. Second, we determine the reference range of the test. Third, we design a fuzzy inference system consisting of membership functions based on the reference range. The inference system plays primary role in the AMDS. Finally, we show the design of AMPS for diabetes and the experimental results.
Keywords :
diseases; fuzzy reasoning; medical diagnostic computing; patient diagnosis; statistical analysis; automated medical diagnosis system; blood test data; diabetes; fuzzy inference system; statistical analysis; Biomedical engineering; Blood; Design engineering; Design methodology; Diabetes; Fuzzy logic; Humans; Medical diagnosis; Medical expert systems; Testing;
Conference_Titel :
Fuzzy Information Processing Society, 2005. NAFIPS 2005. Annual Meeting of the North American
Print_ISBN :
0-7803-9187-X
DOI :
10.1109/NAFIPS.2005.1548611