• DocumentCode
    2643759
  • Title

    Testing Microwave Transmission Lines

  • Author

    Howland, A.R.

  • Volume
    74
  • Issue
    1
  • fYear
    1974
  • fDate
    12-14 June 1974
  • Firstpage
    258
  • Lastpage
    260
  • Abstract
    Direct RF measurement techniques are discussed in terms of their application to testing of long microwave transmission lines such as those used in heavily loaded microwave relay systems or high power RADAR systems. The return loss profile, a measure of transmission line quality, is introduced. Test results presented include data obtained by means of measurement techniques which permit inservice determination of the transmission line operating characteristics.
  • Keywords
    Measurement techniques; Microwave theory and techniques; Power system relaying; Power transmission lines; Propagation losses; Radar applications; Radar measurements; Radio frequency; System testing; Transmission lines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 1974 S-MTT International
  • Conference_Location
    Atlanta, Georgia, USA
  • Type

    conf

  • DOI
    10.1109/MWSYM.1974.1123564
  • Filename
    1123564