    Variable structure control of four pole voltage source inverter for active filtering of nonlinear loads in 3-phase 4-wire systems

  • Author

    Singh, Bhim ; Adha, Anw ; Kothari, D.P. ; Chandra, Ambrish

  • Author_Institution
    Dept. of Electr. Eng., Indian Inst. of Technol., New Delhi, India
  • fYear
    1998
  • fDate
    35964
  • Firstpage
    89
  • Lastpage
    94
  • Abstract
    This paper presents the analysis of four leg voltage source inverter (VSI) used as an active filter (AF) for reactive power compensation, load balancing, harmonic elimination and neutral current compensation in three-phase four-wire nonlinear loads. Variable structure control (VSC) of the average DC bus capacitor of the AF is employed. A hysteresis rule based carrierless pulse width modulation (PWM) current control scheme is employed to generate the gating signals to the switching devices of the active filter. A set of three single-phase diode bridge rectifiers feeding a resistive-capacitive load is used for nonlinear loads on three-phase four-wire power systems. The merits of the proposed method of control are: (1) less complex and reliable active filter configuration; (2) fast controller action; (3) negligible transients in the DC bus voltage of the active filter at the time of instant load changes; (4) gradual convergence of controlled supply currents to new steady state values at the occurrence of abrupt load changes; (5) total harmonic distortion (THD) of the compensated load has been brought well below the standard harmonic specification IEEE-519 limit; (6) neutral current is reduced below 1%; and (7) simultaneous balancing of unbalanced loads. Simulated results confirm the validity of the proposed approach for three-phase (12.5 kW)/two-phase (8.3 kW)/single-phase (4.2 kW) nonlinear loads. The suggested method is expected to be widely used in future for active power filter designs produced for load compensation
  • Keywords
    DC-AC power convertors; PWM invertors; active filters; compensation; control system analysis; control system synthesis; harmonic distortion; load (electric); power filters; power system control; power system harmonics; reactive power control; variable structure systems; 12.5 kW; 4.2 kW; 8.3 kW; IEEE-519; PWM current control scheme; VSI; active power filter; control design; control simulation; gating signals; harmonic elimination; load balancing; neutral current compensation; nonlinear loads; reactive power compensation; resistive-capacitive load; single-phase diode bridge rectifiers; switching devices; three-phase four-wire power systems; total harmonic distortion; variable structure control; voltage source inverter; Active filters; Load management; Power harmonic filters; Power system harmonics; Power system reliability; Power system transients; Pulse power systems; Pulse width modulation; Pulse width modulation inverters; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Quality '98
  • Conference_Location
    Hyderabad
  • Type

    conf

  • DOI
    10.1109/PQ.1998.710360
  • Filename
    710360