Abstract
In telemetry system the technique of voltage comparison has traditionally been used in the monitor receiver to search and to lock a continuous signal or a pulse one, which width is over several millisecond. However, when a signal tested Is a very narrow pulse, it is impossible to use the technique of voltage comparison to catch these signals. The paper introduces a method of counting pulse to search and to lock very narrow pulses (their width>50 ns), which presents a new and a feasible technology for the reception of narrow pulse system
Keywords
counting circuits; frequency control; receivers; signal detection; telemetry; 50 ns; continuous signal; frequency control; monitor receiver; pulse counting; pulse reception; searching; telemetry monitor; telemetry signal; voltage comparison; Bandwidth; Counting circuits; Frequency estimation; Local oscillators; Pulse amplifiers; Pulse modulation; Space vector pulse width modulation; Telemetry; Transmitters; Voltage control;