DocumentCode
2648690
Title
Calculation of breakdown voltages of short air gaps
Author
Hiziroglu, H.R. ; Sebo, S.A.
Author_Institution
Kettering Univ., Flint, MI, USA
Volume
1
fYear
2000
fDate
2000
Firstpage
435
Abstract
In this study, breakdown voltages in air are calculated based on the streamer criterion and compared with experimental data. The calculations are done under standard atmospheric conditions, and the computed breakdown voltages are in good agreement with the experimental findings
Keywords
air gaps; discharges (electric); electric breakdown; atmospheric conditions; breakdown voltage; short air gaps; streamer criterion; Air gaps; Breakdown voltage; Circuit testing; Conductors; Data engineering; Electric breakdown; Electrodes; Length measurement; Shape; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2000 Annual Report Conference on
Conference_Location
Victoria, BC
Print_ISBN
0-7803-6413-9
Type
conf
DOI
10.1109/CEIDP.2000.885318
Filename
885318