DocumentCode :
2655128
Title :
Diagnostic tests of turn-to-turn insulation
Author :
Decner, A. ; Polak, A.
Author_Institution :
Silesian Univ. of Technol., Gliwice, Poland
fYear :
2010
fDate :
6-8 Sept. 2010
Firstpage :
1
Lastpage :
3
Abstract :
The article describes the schema of turn-to-turn insulation and results of simulations and measurements. It shows a new diagnostic method to determinate condition of this insulation. The suggested method can be used in any kind of induction machine and it is easy to use. This method is based on breaking the passage of current in the circuit with tested coil or winding. Breaking a current of the value of 5% of the nominal current generates voltage on the terminals of the winding. This voltage is recorded by digital scope. The frequency of this voltage determines the condition of turn-to-turn insulation.
Keywords :
asynchronous machines; insulation testing; machine insulation; machine testing; machine windings; circuit breaker; diagnostic test; induction machine; machine winding; turn-to-turn insulation; Coils; Current measurement; Frequency measurement; Insulation; Resistance; Voltage measurement; Windings; dielectric measurements; electric machines; rotating machine insulation testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2010 XIX International Conference on
Conference_Location :
Rome
Print_ISBN :
978-1-4244-4174-7
Electronic_ISBN :
978-1-4244-4175-4
Type :
conf
DOI :
10.1109/ICELMACH.2010.5608307
Filename :
5608307