• DocumentCode
    2656803
  • Title

    Magnetic field strength and shape measurements of the Fermilab Main Injector quadrupoles

  • Author

    Harding, D.J. ; Brown, B.C. ; DiMarco, J. ; Glass, H.D. ; Kroc, T.K. ; Martin, P.S. ; Mishra, C.S. ; Walbridge, D.G.C. ; Pewitt, E.G.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    3
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    3269
  • Abstract
    All of the new quadrupoles for the Fermilab Main Injector ring have been built and measured. The magnets are 2.95 m and 2.54 m in length with a 41.7 mm bore. In operation, the magnets run from 1.61 T/m at 8.9 GeV/c to 15.7 T/m at 120 GeV/c and 19.6 T/m at 150 GeV/c. These points correspond to injection, Main Injector fixed target physics and antiproton production, and extraction for transfer to the Tevatron. Good field uniformity is required to ensure a stable beam over the whole acceleration cycle. A significant octupole is included to assist in resonant extraction. The performance of these quadrupoles, in both integrated strength and field uniformity, is presented. All magnets produced meet the accelerator requirements
  • Keywords
    accelerator magnets; magnetic field measurement; particle beam injection; proton accelerators; storage rings; 2.54 m; 2.95 m; Fermilab Main Injector; antiproton production; field uniformity; integrated strength; magnetic field shape measurement; magnetic field strength measurement; octupole; quadrupoles; resonant extraction; Accelerator magnets; Apertures; Boring; Glass; Magnetic field measurement; Magnetic resonance; Magnetic separation; Proton accelerators; Rotation measurement; Shape measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1997. Proceedings of the 1997
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    0-7803-4376-X
  • Type

    conf

  • DOI
    10.1109/PAC.1997.753177
  • Filename
    753177