Abstract
A digital isotopic level gauge of melting steel was developed to measure the mould level more quickly and accurately. This gauge is made of a gamma-ray radioactive source with nonlinear activity distribution, a nuclear detector and a signal processing unit. a simple and practical real time algorithm has been developed by which the pulse count rate is determined and the signal is filtered. Fuzzy logic is also applied to this gauge to adjust the filter parameter automatically according to variations of the input signal. The results of simulation and application demonstrate that the performances of the melting steel level gauge are upgraded and the needs of continuous casting process control are met.
Keywords
casting; fuzzy logic; gauges; melting; moulding; process control; radioactive sources; steel industry; continuous casting process control; digital isotopic level gauge; fuzzy logic; gamma-ray radioactive source; melting steel mould; nonlinear activity distribution; nuclear detector; pulse count rate; signal processing unit; Attenuation measurement; Casting; Detectors; Electric variables measurement; Filters; Fuzzy logic; Pulse measurements; Signal processing; Signal processing algorithms; Steel; Fuzzy tuning; Measurement with isotope; Mould level; Real time algorithm;
fLanguage
English
Publisher
ieee
Conference_Titel
Control Conference, 2008. CCC 2008. 27th Chinese
Conference_Location
Kunming
Print_ISBN
978-7-900719-70-6
Electronic_ISBN
978-7-900719-70-6
Type
conf
DOI
10.1109/CHICC.2008.4604987
Filename
4604987
Link To Document