• DocumentCode
    2657253
  • Title

    Cavity pulling in Galileo passive hydrogen maser

  • Author

    Busca, G. ; Wang, Q. ; Belloni, M. ; Mattioni, L.

  • fYear
    2003
  • fDate
    4-8 May 2003
  • Firstpage
    86
  • Lastpage
    89
  • Abstract
    The paper derives the theoretical expression of the cavity pulling factor in Galileo space passive hydrogen Maser, based on the ´single frequency modulation´. The sensitivity of the cavity pulling vs. the phase selection is deduced in order to account for the experimental errors in the phase adjustments. The theoretical calculation shows the new phase setting exists to achieve a zero cavity pulling, and the preliminary experimental results comparing with the two phase selection are presented.
  • Keywords
    frequency modulation; hydrogen; masers; Galileo space passive hydrogen Maser; H; cavity pulling factor; frequency modulation; phase adjustments; zero cavity pulling; Aerospace electronics; Envelope detectors; Frequency modulation; Hydrogen; Masers; Phase detection; Phase modulation; Prognostics and health management; Resonance; Resonant frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium and PDA Exhibition Jointly with the 17th European Frequency and Time Forum, 2003. Proceedings of the 2003 IEEE International
  • ISSN
    1075-6787
  • Print_ISBN
    0-7803-7688-9
  • Type

    conf

  • DOI
    10.1109/FREQ.2003.1274992
  • Filename
    1274992