DocumentCode
2658727
Title
DSP application of a water-leak detection and isolation algorithm
Author
Begovich, O. ; Valdovinos-Villalobos, G.
Author_Institution
Unidad Guadalajara, CINVESTAV-IPN, Jalisco, Mexico
fYear
2010
fDate
8-10 Sept. 2010
Firstpage
93
Lastpage
98
Abstract
In this paper we present an application of a Digital Signal Processor (DSP) system to detect and isolate a water-leak. The programmed algorithm is based on a Sensitivity Model-Based Approach. The DSP system is tested on-line in a water pipeline prototype. The model used to design the algorithm to isolate the leak is obtained from a Preissmann Scheme. An adaptive estimation of the friction factor is incorporated to attain real-time isolation. Comments about the implementation are given. The estimation results of the leak size and leak position are presented.
Keywords
adaptive estimation; leak detection; pipelines; signal processing; water supply; DSP application; Preissmann Scheme; adaptive estimation; digital signal processor; isolation algorithm; sensitivity model-based approach; water pipeline prototype; water-leak detection; Digital filters; Digital signal processing; Estimation; Friction; Mathematical model; Pipelines; Prototypes; Digital signal processors; leak detection; nonlinear estimation; parameter identification; pipelines; water;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Engineering Computing Science and Automatic Control (CCE), 2010 7th International Conference on
Conference_Location
Tuxtla Gutierrez
Print_ISBN
978-1-4244-7312-0
Type
conf
DOI
10.1109/ICEEE.2010.5608570
Filename
5608570
Link To Document