DocumentCode :
2664378
Title :
Drum boiler reduced model: a singular perturbation method
Author :
Hwang, J.H.
Author_Institution :
Dept. of Electron., Taejon Nat. Univ. of Technol., South Korea
Volume :
3
fYear :
1994
fDate :
5-9 Sep 1994
Firstpage :
1960
Abstract :
This paper describes steam temperature and drum boiler reduced models. They can be derived from a singular perturbation method. Before model reduction, nonlinear dynamic models are divided into two: that is, steam generation system and steam-heating system. The object of steam-heating system control is superheater steam temperature. After designing a steam temperature controller, a drum boiler singularly perturbed system is presented. By selecting controller gains properly, the reduced order drum boiler models may be derived. The drum boiler is a natural recirculation type. The input is fuel and feedwater flow. The output is drum level and main steam flow
Keywords :
boilers; control system synthesis; reduced order systems; singularly perturbed systems; temperature control; controller gains; drum boiler; natural recirculation boiler; nonlinear dynamic models; reduced model; singular perturbation method; steam generation system; steam temperature controller; steam-heating system; superheater steam temperature; Boilers; Control systems; Equations; Fuels; Heating; Nonlinear dynamical systems; Perturbation methods; Rails; Stability; Temperature control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, Control and Instrumentation, 1994. IECON '94., 20th International Conference on
Conference_Location :
Bologna
Print_ISBN :
0-7803-1328-3
Type :
conf
DOI :
10.1109/IECON.1994.398119
Filename :
398119
Link To Document :
بازگشت