DocumentCode
2665295
Title
The “TEM” method of calibration of the pulse high voltage divider
Author
Kniaziev, V.V. ; Kravchenko, V.I. ; Niemchenko, Y.S. ; Lisnoy, I.P.
Author_Institution
Res. & Des. Inst. Molniya, Nat. Tech. Univ. Kharkiv Polytech. Inst., Kharkov, Ukraine
fYear
2010
fDate
6-10 Sept. 2010
Firstpage
259
Lastpage
261
Abstract
The article describes a TEM-method for calibrating high-voltage pulse dividers. The method is based on Etalon-EMP use. It presents the results of method use for determining transient response form and rise time of five types of high-dividers of various designs. The article shows the advantages of this method compared with the known methods.
Keywords
frequency dividers; transient response; Etalon-EMP use; TEM method; high-voltage pulse dividers; rise time; transient response form; Bandwidth; Certification; Oscilloscopes; Switches; Transient response; Ultra wideband technology; Voltage measurement; High-voltage pulse dividers; metrological certification; rise time; transient response;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrawideband and Ultrashort Impulse Signals (UWBUSIS), 2010 5th International Conference on
Conference_Location
Sevastopol
Print_ISBN
978-1-4244-7470-7
Electronic_ISBN
978-1-4244-7469-1
Type
conf
DOI
10.1109/UWBUSIS.2010.5609119
Filename
5609119
Link To Document