• DocumentCode
    2665295
  • Title

    The “TEM” method of calibration of the pulse high voltage divider

  • Author

    Kniaziev, V.V. ; Kravchenko, V.I. ; Niemchenko, Y.S. ; Lisnoy, I.P.

  • Author_Institution
    Res. & Des. Inst. Molniya, Nat. Tech. Univ. Kharkiv Polytech. Inst., Kharkov, Ukraine
  • fYear
    2010
  • fDate
    6-10 Sept. 2010
  • Firstpage
    259
  • Lastpage
    261
  • Abstract
    The article describes a TEM-method for calibrating high-voltage pulse dividers. The method is based on Etalon-EMP use. It presents the results of method use for determining transient response form and rise time of five types of high-dividers of various designs. The article shows the advantages of this method compared with the known methods.
  • Keywords
    frequency dividers; transient response; Etalon-EMP use; TEM method; high-voltage pulse dividers; rise time; transient response form; Bandwidth; Certification; Oscilloscopes; Switches; Transient response; Ultra wideband technology; Voltage measurement; High-voltage pulse dividers; metrological certification; rise time; transient response;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrawideband and Ultrashort Impulse Signals (UWBUSIS), 2010 5th International Conference on
  • Conference_Location
    Sevastopol
  • Print_ISBN
    978-1-4244-7470-7
  • Electronic_ISBN
    978-1-4244-7469-1
  • Type

    conf

  • DOI
    10.1109/UWBUSIS.2010.5609119
  • Filename
    5609119