DocumentCode :
2665295
Title :
The “TEM” method of calibration of the pulse high voltage divider
Author :
Kniaziev, V.V. ; Kravchenko, V.I. ; Niemchenko, Y.S. ; Lisnoy, I.P.
Author_Institution :
Res. & Des. Inst. Molniya, Nat. Tech. Univ. Kharkiv Polytech. Inst., Kharkov, Ukraine
fYear :
2010
fDate :
6-10 Sept. 2010
Firstpage :
259
Lastpage :
261
Abstract :
The article describes a TEM-method for calibrating high-voltage pulse dividers. The method is based on Etalon-EMP use. It presents the results of method use for determining transient response form and rise time of five types of high-dividers of various designs. The article shows the advantages of this method compared with the known methods.
Keywords :
frequency dividers; transient response; Etalon-EMP use; TEM method; high-voltage pulse dividers; rise time; transient response form; Bandwidth; Certification; Oscilloscopes; Switches; Transient response; Ultra wideband technology; Voltage measurement; High-voltage pulse dividers; metrological certification; rise time; transient response;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrawideband and Ultrashort Impulse Signals (UWBUSIS), 2010 5th International Conference on
Conference_Location :
Sevastopol
Print_ISBN :
978-1-4244-7470-7
Electronic_ISBN :
978-1-4244-7469-1
Type :
conf
DOI :
10.1109/UWBUSIS.2010.5609119
Filename :
5609119
Link To Document :
بازگشت