• DocumentCode
    2665382
  • Title

    On the design of fully integrated charge preamplifiers for the Superconducting Supercollider

  • Author

    Ling, K.Y. ; VanPeteghem, P.M. ; Lee, S.Y. ; Liu, H.H. ; Sanchez, H. ; DiBitonto, D.

  • Author_Institution
    Dept. of Electr. Eng., Texas A&M Univ., College Station, TX, USA
  • fYear
    1990
  • fDate
    1-3 May 1990
  • Firstpage
    3221
  • Abstract
    As a case study of a BiFET prototype charge preamplifier to be used for particle detection in the Superconducting Supercollider which has been tested up to a total gamma dose of 1.44 Mrad and a neutron fluence of 2×1013 n/cm2 is presented. Some design considerations and measurement results are discussed. The presented BiFET prototype combines low noise, low power consumption, and high speed. This prototype can be expected to perform well in the portions of the Superconducting Supercollider where the total doses do not exceed 200 to 300 krad per year
  • Keywords
    linear integrated circuits; monolithic integrated circuits; nuclear electronics; particle detectors; preamplifiers; 1.44×106 rad; BiFET prototype; Superconducting Supercollider; fully integrated charge preamplifiers; high speed; low noise; low power consumption; monolithic IC; particle detection; Capacitance; Capacitors; Circuits; Costs; Detectors; Electrons; Energy consumption; Manufacturing; Preamplifiers; Space technology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Circuits and Systems, 1990., IEEE International Symposium on
  • Conference_Location
    New Orleans, LA
  • Type

    conf

  • DOI
    10.1109/ISCAS.1990.112697
  • Filename
    112697