DocumentCode :
2668475
Title :
Soft sensor for flow measurement: overshot regulator
Author :
Wendt, Carl ; Weyer, Erik ; Mareels, Iven
Author_Institution :
Dept. of Electr. & Electron. Eng., Melbourne Univ., Parkville, Vic., Australia
fYear :
1999
fDate :
1999
Firstpage :
471
Lastpage :
475
Abstract :
Flow data for an open channel collected at an overshot regulator under submerged and closed loop operating conditions has been modelled according to traditional static hydraulic equations, and the parameters estimated. The parameter estimation task is based on system identification techniques. Further simplifications in order to improve the performance of the identified equations have been suggested and evaluated on the data set. These simplified model structures have been found to be better performed
Keywords :
closed loop systems; flow control; flow measurement; hydraulic systems; parameter estimation; water supply; closed loop operating conditions; flow control; flow measurement; irrigation; open channel; overshot regulator; parameter estimation; soft sensor; static hydraulic equations; submerged gates; submerged operating conditions; system identification techniques; Australia; Equations; Fluid flow measurement; Gold; Irrigation; Parameter estimation; Regulators; Sensor phenomena and characterization; Sensor systems; System identification;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Information, Decision and Control, 1999. IDC 99. Proceedings. 1999
Conference_Location :
Adelaide, SA
Print_ISBN :
0-7803-5256-4
Type :
conf
DOI :
10.1109/IDC.1999.754202
Filename :
754202
Link To Document :