  • Abstract
    The contact less energy transfer requires a transformer with air-gap. So organized transformer suffer with the no-negligible leakage inductance. When hard switching principle has been used the undesirable high surge voltage appears on the semiconductor elements. This paper treats the 500 W AC-DC converter based on HF-AC resonant link circuit in order to avoid the high surge voltage problems
  • Keywords
    AC-DC power convertors; surges; transformers; 500 W; AC-DC converter; HF-AC resonant-link circuit; contact-less energy transfer; hard switching; semiconductor elements; surge voltage; transformer; AC-DC power converters; Air gaps; Energy exchange; Magnetic separation; Power electronics; RLC circuits; Rectifiers; Resonance; Robots; Surges;