    Beat-to-beat detection of ventricular late potentials and His potential using the adaptive orthogonal projection

  • Author

    Bensadoun, Yasmina ; Novakov, Emile ; Raoof, Kosai ; Defaye, Pascal

  • Author_Institution
    LIME, Univ. Joseph Fourier, Grenoble, France
  • Volume
    1
  • fYear
    1997
  • fDate
    30 Oct-2 Nov 1997
  • Firstpage
    81
  • Abstract
    Noninvasive techniques to record the activation wave of His potential and ventricular late potentials have so far depended largely on signal averaging. Although this approach produces representative signals, any beat-to-beat variations are removed by the averaging process. These beat-to-beat variations are important in the diagnosis of many heart anomalies, particularly arrhythmias. The paper describes an experimental system which can detect His potential and ventricular late potentials at the body surface while preserving beat-to-beat variations. The system uses a number of different techniques, but an important feature is the use of blind separation sources using higher order statistics for the removal of mains interference and multidimensional adaptive orthogonal projection succeeded by an adaptive filtering to cancel random noises such as electrode noise, electronic noise, motion artefacts and electromyographic (EMG) signals. This technique was evaluated by using real cardiac signals recorded on four channels, by an array of four small surface electrode pairs
  • Keywords
    electrocardiography; medical signal detection; medical signal processing; ECG analysis; EMG signals; His potential; adaptive filtering; adaptive orthogonal projection; arrhythmias; beat-to-beat detection; beat-to-beat variations; blind separation sources; electrode noise; electrodiagnostics; electronic noise; heart anomalies; higher order statistics; mains interference removal; motion artefacts; random noises cancellation; small surface electrode pairs; ventricular late potentials; Adaptive filters; Electrodes; Electromyography; Heart; Higher order statistics; Interference cancellation; Multidimensional systems; Noise cancellation; Noninvasive treatment; Signal processing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-4262-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.1997.754469