DocumentCode
2673789
Title
Corrosion of precious metal plated copper alloys due to mixed flowing gas exposure
Author
Geckle, Raymond J. ; Mroczkowski, Robert S.
Author_Institution
Amp Inc., Harrisburg, PA, USA
fYear
1990
fDate
20-24 Aug 1990
Firstpage
193
Lastpage
202
Abstract
Corrosion of precious-metal-plated copper alloys after exposure to mixed flowing gas environments is studied. Six copper alloys used in electronic connectors were selected for study. All alloys were plated with a nickel underplate followed by a precious metal surface plating of gold or gold-flashed palladium. The coupons were then exposed to a mixed flowing gas environment containing chlorine, hydrogen sulfide, and nitrogen oxide. The base metal corrosion products arising from these exposures migrate to the surface through originating plating defects, creating films and corrosion mounds on the surface and large etch pits in the copper alloy substrate. The surface corrosion products were analyzed by an electron microprobe and found to be very complex. All constituents of the copper alloys, as well as nickel from the underplate, were found in the corrosion products. The metals were found to be in combination with oxygen, chlorine, and sulfur in varying amounts and distributions. Examples of the corrosion products and processes are discussed
Keywords
corrosion testing; electric connectors; electronic equipment testing; Cl2; Cu alloys; H2S; base metal corrosion products; electron microprobe; electronic connectors; etch pits; mixed flowing gas exposure; plating defects; Connectors; Copper alloys; Corrosion; Electrons; Etching; Gold alloys; Hydrogen; Nickel alloys; Nitrogen; Palladium;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Contacts, 1990. Proceedings of the Thirty-Sixth IEEE Holm Conference on ... and the Fifteenth International Conference on Electrical Contacts
Conference_Location
Montreal, Que.
Type
conf
DOI
10.1109/HOLM.1990.113013
Filename
113013
Link To Document