• DocumentCode
    2674860
  • Title

    Operational Status and Stability Improvement of Klystron-Modulator System for PAL 2.5-GeV Electron Linac

  • Author

    Park, Soung Soo ; Kim, Sang Hee ; Kim, Sung Chul ; Han, Yeung Jin ; Huang, Jung Yun ; Choi, Jin Huk ; Nam, Sang Hoon

  • Author_Institution
    Pohang Accelerator Lab./POSTECH, Kyung-Buk
  • fYear
    2006
  • fDate
    14-18 May 2006
  • Firstpage
    298
  • Lastpage
    301
  • Abstract
    The klystron-modulator (K&M) system of the Pohang Accelerator Laboratory (PAL) has been supplying high power microwaves for the acceleration of 2.5 GeV electron beams since October 2002. There are 12 sets of K&M systems to accelerate electron beams to 2.5 GeV nominal beam energy. One module of the K&M system consists of an 80 MW S-band (2856 MHz) klystron tube and the matching 200 MW modulator. The matching modulators of 200-MW (400 kV, 500 A) can provide a flattop pulse width of 4.4 infinsec with a maximum pulse repetition rate of 120-Hz at the full power level. The total accumulated high-voltage run-time of the oldest unit among 12 units has reached nearly 88,000 hours as of Dec. 2005, and the summation of all the units high voltage run-time is approximately 970,000 hours. The overall system availability is well over 95%. There have been continuous efforts to improve the klystron-modulator system and make it more stable and reliable. In order to obtain low electron beam energy fluctuation, the pulse-to-pulse beam voltage regulation is required to be less than +/- 0.5 %. In a conventional resonant charging pulse modulator, the regulation is usually achieved by using a de-Q´ing circuit. In this paper, we are able to review overall system performance of the high-power K&M system and the operational characteristics of the klystrons and thyratrons, and overall system´s availability analysis from Jan. to Dec. 2005
  • Keywords
    electron accelerators; klystrons; linear accelerators; modulators; thyratrons; voltage control; 120 Hz; 2856 MHz; 400 kV; 500 A; 80 MW; PAL; Pohang Accelerator Laboratory; electron beam acceleration; electron linac; high-power K&M system; klystron-modulator system; matching modulators; operational characteristics; pulse-to-pulse beam voltage regulation; thyratrons; Acceleration; Availability; Electron beams; Klystrons; Linear particle accelerator; Pulse modulation; Pulse width modulation; Runtime; Space vector pulse width modulation; Stability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator Symposium, 2006. Conference Record of the 2006 Twenty-Seventh International
  • Conference_Location
    Arlington, VA
  • Print_ISBN
    1-4244-0018-X
  • Electronic_ISBN
    1-4244-0019-8
  • Type

    conf

  • DOI
    10.1109/MODSYM.2006.365242
  • Filename
    4216194