DocumentCode
2676070
Title
Design of triode-type Magnetron Injection Gun for 460 GHz, 50–100 W, gyrotron for Medical Spectroscopy
Author
Jain, Chinmay A. ; Verma, Ankit ; Kumar, Ashish ; Krishna, P. Vamshi ; Kartikeyan, M.V. ; Illy, Stefan ; Borie, E. ; Thumm, M.
Author_Institution
Dept. Electron. & Comput. Eng., Indian Inst. of Technol., Roorkee, India
fYear
2011
fDate
2-7 Oct. 2011
Firstpage
1
Lastpage
2
Abstract
This paper presents the design of a triode-type Magnetron Injection Gun (MIG) for a 460 GHz, 50-100 W gyrotron for Medical Spectroscopy operating at 25 KV and 0.1 A. The design is facilitated by determining the initial design following analytical expressions of Baird and Lawson1 and then carrying out the design optimization using available ESRAY trajectory program2. This paper also presents the design of magnetic guidance system.
Keywords
biomedical electronics; electron guns; gyrotrons; magnetrons; submillimetre wave spectroscopy; triodes; Baird analytical expressions; ESRAY trajectory program; Lawson analytical expressions; MIG; current 0.1 A; design optimization; frequency 460 GHz; magnetic guidance system; medical spectroscopy; power 50 W to 100 W; triode-type magnetron injection gun; voltage 25 kV; Anodes; Cathodes; Cavity resonators; Coils; Gyrotrons; Magnetic fields; Magnetic resonance;
fLanguage
English
Publisher
ieee
Conference_Titel
Infrared, Millimeter and Terahertz Waves (IRMMW-THz), 2011 36th International Conference on
Conference_Location
Houston, TX
ISSN
2162-2027
Print_ISBN
978-1-4577-0510-6
Electronic_ISBN
2162-2027
Type
conf
DOI
10.1109/irmmw-THz.2011.6105105
Filename
6105105