Abstract :
We investigated an all-electronic fmcw millimeter / Terahertz wave computed tomography system with short acquisition time and operating frequencies of 230-320 GHz or alternatively 70-110 GHz. The 3D computed tomography reconstruction of several measured examples is presented.
Keywords :
image reconstruction; millimetre wave imaging; optical tomography; submillimetre wave imaging; terahertz wave imaging; 3D computed tomography reconstruction; all-electronic 3D computed THz tomography; all-electronic FMCW millimeter-terahertz wave computed tomography system; frequency 230 GHz to 320 GHz; frequency 70 GHz to 110 GHz; short acquisition time; Absorption; Computed tomography; Dynamic range; Image edge detection; Image reconstruction; Metals; Polymer foams;