DocumentCode
2678972
Title
Negative pressure wave-flow testing gas pipeline leak based on wavelet transform
Author
Ma, Chunlong ; Yu, Shuhan ; Huo, Jinming
Author_Institution
Inf. Eng. Dept., Chang Chun Univ., Jilin, China
Volume
5
fYear
2010
fDate
24-26 Aug. 2010
Firstpage
306
Lastpage
308
Abstract
To solve the problem of high false alarm rate and low positioning accuracy in the gas leak location detection, a new method is designed, in which wavelet transform is used to extract gas leak negative pressure wave signal, the gas leaks and positioning can be detected by using the method of negative pressure wave combined with flow balance. An algorithm of extracting negative pressure signal through wavelet transform is proposed and a method of negative pressure signal-flow rate detecting and positioning is provided. A negative pressure wave-flow testing gas pipeline leak system based on wavelet transform is designed. The positioning accuracy of the system reaches ± 1% of pipe length, and the false alarm rate is reduced.
Keywords
leak detection; mechanical testing; natural gas technology; wavelet transforms; false alarm rate; gas leak location detection; gas leak negative pressure wave signal; negative pressure wave-flow testing gas pipeline leak system; positioning accuracy; wavelet transform; Monitoring; Transforms; flow; negative pressure wave; positioning; wavelet transform;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer, Mechatronics, Control and Electronic Engineering (CMCE), 2010 International Conference on
Conference_Location
Changchun
Print_ISBN
978-1-4244-7957-3
Type
conf
DOI
10.1109/CMCE.2010.5609975
Filename
5609975
Link To Document