DocumentCode
2681356
Title
Cryogenic All Sold-State Millimeter-Wave Receivers for Airborne Radiometry
Author
Vowinkel, B. ; Gruner, K. ; Suss, H. ; Reinert, W.
fYear
1983
fDate
May 31 1983-June 3 1983
Firstpage
566
Lastpage
568
Abstract
Cryogenic receiver modules for 90 and 140 GHz have been developed that are part of an airborne imaging system. They consist of Schottky-barrier mixers followed by GaAs-FET IF amplifiers. The DSB receiver noise temperatures are 210 K for the 90 GHz and 250 K for the 140 GHz system. The instantaneous bandwidth is 2.5 GHz for both front-ends. Results of some flight tests are presented.
Keywords
Band pass filters; Bandwidth; Cryogenics; Detectors; Frequency response; High-resolution imaging; Image resolution; Microwave radiometry; Schottky diodes; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Symposium Digest, 1983 IEEE MTT-S International
Conference_Location
Boston, MA, USA
ISSN
0149-645X