Abstract
Grid connected voltage source inverters may be controlled in the stationary reference frame by means of the infinite impulse response (IIR) P+Resonat regulator. This regulator is able to correctly track fixed frequency sinusoidal references, but does not perform well if the frequency of the electric grid voltage is varied. In order to avoid the lack of precision to track variable frequency sinusoidal references, an adaptive IIR filter structure is proposed which offers good tracking properties even if the frequency of the grid voltage varies. This filter adapts its coefficients in real time and is inherently stable no matter the adaptation process, thus overcoming one of the most important drawbacks of the IIR filter structure. Furthermore, this structure is perfectly suited to be programmed in fixed point digital signal processors (DSPs) because of some important numeric properties, i.e., it has a high mapping precision and a low round-off accumulation, and it avoids quantization limit cycle oscillations. The proposed adaptive controller has been tested by means of the TI TMS320F2812 DSP. The obtained experimental results show up that this controller allows the correct tracking of a sinusoidal reference, even if this reference is time variant.
Keywords
IIR filters; adaptive control; adaptive filters; digital control; digital signal processing chips; frequency control; invertors; oscillations; power grids; DSP; TI TMS320F2812 DSP; adaptation process; adaptive IIR filter structure; adaptive digital control technique; electric grid voltage frequency; fixed frequency sinusoidal references; fixed point digital signal processors; grid connected voltage source inverters; grid voltage; infinite impulse response IIR P; infinite impulse response P; low round-off accumulation; mapping precision; numeric properties; quantization limit cycle oscillations; real-time system; sinusoidal reference; stationary reference frame control; variable frequency sinusoidal reference tracking; Adaptive filters; Band pass filters; IIR filters; Inverters; Power harmonic filters; Resonant frequency; Transfer functions; Adaptive control; converters; current control; digital control inverters; photovoltaic systems; power conversion harmonics; power quality; solar energy; three-phase electric power;
fLanguage
English
Journal_Title
Industrial Informatics, IEEE Transactions on
Publisher
ieee
ISSN
1551-3203
Type
jour
DOI
10.1109/TII.2012.2225437
Filename
6340337
Link To Document