  • Abstract
    Glomerular Filtration Rate (GFR) is an important merit in evaluating the renal function. A common way of GFR determination is utilizing the Gamma camera scintigraphy with 99mTc-DTPA, manually delineating the region of interest (ROI) and calculating GFR via the Gates method. However, the manual ROI delineation could be impossible due to the poor quality of the scintigraphic image for patients with low renal function. In this work we present a CT-assisted ROI acquisition method for patients with at least a severely damaged kidney, who usually undergo the scintigraphy and the CT examination separately or jointly. Nineteen patients (10 men, 9 women, age range 21-87y, mean 58.0 ± 20.2y) were involved. First of all, the scintigraphic image was summed from 2-min to 3-min after the bolus injection to form a composite image of scintigraphy (SIm), on which the ROI of the relative better kidney was delineated manually. Then a binary image (SBIm) was formed only containing the ROI of the better kidney. Secondly, slices of the CT image containing the kidney structure were summed to obtain the projection image (CIm), on which two kidney ROIs were also drawn manually. A structural binary image (CBIm) was then formed accordingly. Thirdly, the CBIm was resized and matched to the SBIm, and used as a mask to filter the SIm to produce the ROI of the poorer kidney that was not drawn on the SIm. After that, sub renal background ROIs were extracted on the SIm proportionally and automatically. Finally, the GFR was calculated using the Gates method with the kidney ROIs and the background ROIs. To evaluate our method, two clinicians with about 5-year clinical experience drew kidney ROIs manually and also employed our CT-assisted method to detect ROIs. We compared the consistence of the method of manual delineation and ours in terms of the GFR. The results showed that the CT-assisted method was more reproducible when applied to the patient data.
  • Keywords
    computerised tomography; kidney; medical image processing; radioisotope imaging; 99mTc-DTPA scintigraphy; CT-assisted region of interest acquisition method; Gates method; gamma camera scintigraphy; glomerular filtration rate; kidney; renal function evaluation; structural binary image; Computed tomography; Educational institutions; Filtration; Kidney; Logic gates; Manuals; 99mTc-DTPA scintigraphy; CT-assisted; Glomerular filtration rate; region of interest;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Biotechnology (iCBEB), 2012 International Conference on
  • Conference_Location
    Macau, Macao
  • Print_ISBN
    978-1-4577-1987-5
  • Type

    conf

  • DOI
    10.1109/iCBEB.2012.464
  • Filename
    6245280