• DocumentCode
    2683451
  • Title

    Robust contour tracking in echocardiographic sequences

  • Author

    Jacob, Gary ; Noble, J. Alison ; Blake, Andrew

  • Author_Institution
    Dept. of Eng. Sci., Oxford Univ., UK
  • fYear
    1998
  • fDate
    4-7 Jan 1998
  • Firstpage
    408
  • Lastpage
    413
  • Abstract
    In this paper we present an evaluation of a robust visual image tracker on echocardiographic image sequences. We show how the tracking framework can be customised to define an appropriate shape-space that describes heart shape deformations that can be learnt from a training data set. We also investigate an energy-based temporal boundary enhancement method to improve image feature measurement. Preliminary results are presented demonstrating tracking on real normal heart motion data sequences and synthesised and real abnormal heart motion data sequences. We conclude by discussing some of our current research efforts
  • Keywords
    echocardiography; image sequences; medical image processing; contour tracking; echocardiographic sequences; heart motion data sequences; image sequences; visual image tracker; Heart; Image analysis; Image sequence analysis; Image sequences; Jacobian matrices; Noise robustness; Noise shaping; Shape; Training data; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Vision, 1998. Sixth International Conference on
  • Conference_Location
    Bombay
  • Print_ISBN
    81-7319-221-9
  • Type

    conf

  • DOI
    10.1109/ICCV.1998.710751
  • Filename
    710751