Abstract :
When the nozzle is working, there is large amount of hot gas at the interface of the carbon-carbon(C/C) exit-cone because of the pyrolysis of insulator. The hot gas may cause high pressure which may impact the reliability of the joint structure. So the high temperature and pressure measurement were developed to measure the temperature and pressure at the interface of the C/C exit-cone and the insulator. The result shows that the hot gas makes pressure at the interface of the C/C exit-cone. Different exit-cone materials, pressures are different. The higher the density of the C/C material, the higher is the pressure. The effect of the pyrolysis hot gas to the reliability of the joint structure was also analyzed.
Keywords :
nozzles; pyrolysis; reliability; structural engineering; temperature measurement; carbon-carbon exit cone; insulator; nozzle; pressure measurement; pyrolysis hot gas pressure; structure reliability; temperature measurement; Joints; Materials; Pressure measurement; Stress; Temperature distribution; Temperature measurement; Weaving; C/C exit-cone; pyrolysis; silica cloth phenolic insulator; thermocouple; thermometry;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Reliability, Maintainability and Safety (ICRMS), 2011 9th International Conference on
Conference_Location :
Guiyang
Print_ISBN :
978-1-61284-667-5
Type :
conf
DOI :
10.1109/ICRMS.2011.5979313
Filename :
5979313
Link To Document :
بازگشت