DocumentCode :
2685129
Title :
Analysis of PM synchronous motor drive failures during flux weakening operation
Author :
Bianchi, N. ; Bolognani, S. ; Zigliotto, M.
Author_Institution :
Dept. of Electr. Eng., Padova Univ., Italy
Volume :
2
fYear :
1996
fDate :
23-27 Jun 1996
Firstpage :
1542
Abstract :
Under flux weakening operation, the phase emf of a PM synchronous motor can be extremely high; this paper investigates the effects on currents, voltages and torque of different drive failures occurring under flux weakening operation, as a starting point for a successful design of an effective system protection and a fault-tolerant control
Keywords :
failure analysis; machine control; magnetic flux; permanent magnet motors; synchronous motor drives; synchronous motor protection; torque; PM synchronous motor drive failures; currents; failure analysis; fault-tolerant control; flux weakening operation; phase emf; system protection; torque; voltages; Brushless DC motors; Circuit faults; Control systems; DC motors; Failure analysis; Fault tolerance; Hysteresis motors; Permanent magnet motors; Pulse width modulation inverters; Synchronous motors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1996. PESC '96 Record., 27th Annual IEEE
Conference_Location :
Baveno
ISSN :
0275-9306
Print_ISBN :
0-7803-3500-7
Type :
conf
DOI :
10.1109/PESC.1996.548786