Abstract :
The complete severance of the extensor mechanism in the proximal interphalangeal joint is a difficult injury to treat successfully. In this study, the applicability of finite element analysis for comparing the strength of various types of repair was investigated. Load-deflection tests were performed on severed tendons that were repaired using the standard and Snow method, and the results were compared with the maximum stresses associated with the load-deflection characteristics of the finite element models of these repairs. The results from both set of tests were found to agree qualitatively
Keywords :
biological tissues; biomechanics; finite element analysis; orthopaedics; stress analysis; stress-strain relations; surgery; viscoelasticity; Snow method; complete extensor mechanism severance; extensor tendon suture techniques; finite element analysis; load-deflection tests; maximum stresses; proximal interphalangeal joint; retrograde flap; severed tendons; strength comparison; viscoelastic properties; Educational institutions; Fingers; Finite element methods; Injuries; Medical treatment; Performance evaluation; Snow; Stress; Tendons; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioengineering Conference, 1999. Proceedings of the IEEE 25th Annual Northeast
Conference_Location :
West Hartford, CT
Print_ISBN :
0-7803-5486-9
Type :
conf
DOI :
10.1109/NEBC.1999.755730
Filename :
755730
Link To Document :
بازگشت