Title :
Wet gas flow modeling for the straight section of throat-extended Venturi meter
Author :
Zhou, Wanlu ; Xu, Lijun ; Li, Xiaomin
Author_Institution :
Sch. of Instrum. Sci. & Opto-Electron. Eng., Beihang Univ., Beijing, China
Abstract :
In this paper, wet gas flow modeling for the straight section of a throat-extended Venturi meter was studied. A static model based on the separated flow theory was presented. Experiments were carried out within static pressure range of 0.26~0.86 MPa, gas volumetric flowrate range of 80~120 m3/h, water volumetric flowrate range of 0.3~4.5 m3/h and quality range of 0.07~0.36. It was obtained that the root mean square of the relative errors of the DP over the straight section calculated from the static model was 8.82%.
Keywords :
flowmeters; pressure measurement; relative errors; root mean square; straight section; throat-extended Venturi meter; wet gas flow modeling; Acceleration; Chemistry; Design optimization; Equations; Fluid flow; Fluid flow measurement; Geometry; Instruments; Power measurement; Root mean square; Differential Pressure (DP); Throat-Extended Venturi Meter (TEVM); flow modeling; straight section; wet gas metering;
Conference_Titel :
Instrumentation and Measurement Technology Conference (I2MTC), 2010 IEEE
Conference_Location :
Austin, TX
Print_ISBN :
978-1-4244-2832-8
Electronic_ISBN :
1091-5281
DOI :
10.1109/IMTC.2010.5488011