DocumentCode :
2688179
Title :
Measurement of TDC in Engine by Microwave Technique
Author :
Yamanaka, T. ; Esaki, M. ; Kinoshita, M.
fYear :
1985
fDate :
4-6 June 1985
Firstpage :
647
Lastpage :
650
Abstract :
A microwave technique for determining the top dead center (TDC) of engine has heen developed. Factors affecting systematic errors were investigated experimentally using high resolution pulses (0.015°) and a uniquely designed probe. Consideration is made for cycle change of the cylinder wall temperature. The main factors are attributable to the thermal expansion of the cylinder and the cylinder pressure change. Under well defined engine conditions, accuracy of +-0.1° is possible for TDC measurement.
Keywords :
Combustion; Conducting materials; Detectors; Diesel engines; Engine cylinders; Microwave measurements; Microwave theory and techniques; Probes; Pulse amplifiers; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 1985 IEEE MTT-S International
Conference_Location :
St. Louis, MO, USA
ISSN :
0149-645X
Type :
conf
DOI :
10.1109/MWSYM.1985.1132064
Filename :
1132064
Link To Document :
بازگشت