DocumentCode
2691636
Title
Enhanced harmonic injection for determination of harmonic loss in induction machines
Author
Bradley, K.J. ; Clare, J.C. ; Magill, R. ; Ferrah, A. ; Wheeler, P. ; Sewell, P. ; Cao, W.
Author_Institution
Nottingham Univ., UK
fYear
2000
fDate
2000
Firstpage
212
Lastpage
217
Abstract
This paper compares direct, by calorimeter, and indirect, by harmonic injection, methods for measurement of inverter induced, harmonic power loss across a range of induction motors from 1.1 to 30 kW. Techniques to obtain the necessary experimental precision are described. Comparisons between segregated losses for the machines operating on sinusoidal supplies show a link between iron loss and high frequency PWM induced loss. Iron loss is not a constant proportion of total loss for all machines so that neither is harmonic loss independent of machine design
Keywords
PWM invertors; induction motors; loss measurement; power conversion harmonics; 1.1 to 30 kW; enhanced harmonic injection; harmonic loss determination; high frequency PWM induced loss; induction machines; induction motors; inverter induced harmonic power loss; iron loss; loss measurement; segregated losses; sinusoidal supplies;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics and Variable Speed Drives, 2000. Eighth International Conference on (IEE Conf. Publ. No. 475)
Conference_Location
London
Print_ISBN
0-85296-729-2
Type
conf
DOI
10.1049/cp:20000247
Filename
888924