• DocumentCode
    2694383
  • Title

    High-voltage transmission line transformer based on modern cable technology

  • Author

    Lindblom, A. ; Appelgren, Patrik ; Larsson, Anders ; Nyholm, Sten E. ; Isberg, Jan ; Bernhoff, Hans

  • Author_Institution
    Divisionfor Electricity & Lightning Res., Uppsala Univ., Sweden
  • Volume
    2
  • fYear
    2003
  • fDate
    15-18 June 2003
  • Firstpage
    939
  • Abstract
    A high-voltage transmission line pulse transformer has been constructed based on modern cable technology. The transformer has been successfully tested for secondary voltages up to 85 kV. The high-voltage cable is equipped with a resistive layer (semicon) on the inner conductor and on the inside of the outer conductor. Semicon cables are commonly used in high-voltage transmission of electrical power. This article describes a transformer design that uses the screen in the coaxial cable as primary winding and the inner conductor as secondary. The coupling factor for the single layer transformer is 0.8. This high coupling factor is achieved due to the coaxial structure. The single layer transformer was tested in an existing power-conditioning system, in which an output voltage of 85 kV was achieved. The pulse had 1-/spl mu/s duration over a 15-/spl Omega/ load. The high voltage cable with PEX insulation proved to withstand very high stress (85 kV/mm). This type of transformer is useful in applications where weight is an important factor. The simple design ensures low cost manufacturing.
  • Keywords
    coaxial cables; power cables; power transmission lines; pulse transformers; 1 mus; 15 ohm; 85 kV; PEX insulation; coaxial structure; coupling factor; high-voltage transmission line pulse transformer; inner conductor; modern cable technology; outer conductor; power-conditioning system; primary winding; resistive layer; secondary voltages; semicon cables; single layer transformer; stress; Coaxial cables; Coaxial components; Conductors; Couplings; Power cables; Power transformer insulation; Power transmission lines; Pulse transformers; Testing; Transmission lines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2003. Digest of Technical Papers. PPC-2003. 14th IEEE International
  • Conference_Location
    Dallas, TX, USA
  • Print_ISBN
    0-7803-7915-2
  • Type

    conf

  • DOI
    10.1109/PPC.2003.1277965
  • Filename
    1277965