DocumentCode :
2695579
Title :
Impact of Dielectric Loss Tangent on the Performance of Millimeter Wave Ferrite Circulators
Author :
Harrison, G.R. ; Thompson, S.B. ; Vaughn, J.T.
Volume :
2
fYear :
1987
fDate :
May 9 1975-June 11 1987
Firstpage :
989
Lastpage :
991
Abstract :
A ferrite circulator can be modeled as a dielectric resonator whose unloaded Q is a function of dielectric loss. This model predicts that when loss tangents of ferrite materials are increased from 0.0002 to 0.002, circulator insertion loss increases by about 0.14 dB. Experimental measurements confirm that loss tangents significantly less than 0.001 are required to achieve low insertion loss, high performance, millimeter wave circulators.
Keywords :
Circulators; Dielectric loss measurement; Dielectric losses; Dielectric materials; Dielectric measurements; Ferrites; Insertion loss; Millimeter wave measurements; Performance loss; Predictive models;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 1987 IEEE MTT-S International
Conference_Location :
Palo Alto, CA, USA
ISSN :
0149-645X
Type :
conf
DOI :
10.1109/MWSYM.1987.1132589
Filename :
1132589
Link To Document :