Title :
Impact of Dielectric Loss Tangent on the Performance of Millimeter Wave Ferrite Circulators
Author :
Harrison, G.R. ; Thompson, S.B. ; Vaughn, J.T.
fDate :
May 9 1975-June 11 1987
Abstract :
A ferrite circulator can be modeled as a dielectric resonator whose unloaded Q is a function of dielectric loss. This model predicts that when loss tangents of ferrite materials are increased from 0.0002 to 0.002, circulator insertion loss increases by about 0.14 dB. Experimental measurements confirm that loss tangents significantly less than 0.001 are required to achieve low insertion loss, high performance, millimeter wave circulators.
Keywords :
Circulators; Dielectric loss measurement; Dielectric losses; Dielectric materials; Dielectric measurements; Ferrites; Insertion loss; Millimeter wave measurements; Performance loss; Predictive models;
Conference_Titel :
Microwave Symposium Digest, 1987 IEEE MTT-S International
Conference_Location :
Palo Alto, CA, USA
DOI :
10.1109/MWSYM.1987.1132589