• DocumentCode
    2707483
  • Title

    Partial discharge propagation model and location estimate

  • Author

    Du, Zhifang ; Mashikian, Matthew S. ; Palmieri, Francesco

  • Author_Institution
    Electr. Insulation Res. Center, Connecticut Univ., Storrs, CT, USA
  • fYear
    1994
  • fDate
    5-8 Jun 1994
  • Firstpage
    99
  • Lastpage
    102
  • Abstract
    This paper describes a partial discharge propagation model and a location estimate which uses digital signal processing techniques. The model and the estimate are developed for an instrument which is capable of locating partial discharge sites in power cables non-destructively and in situ. Since the model utilizes actual cable response to partial discharge signals, it provides an excellent waveform match between simulations and measurements. The estimator can locate partial discharge sites in noisy environments with an error not exceeding 2 m. Applications of this model to field test data are also discussed
  • Keywords
    nondestructive testing; partial discharges; power cable insulation; power cable testing; cable response; digital signal processing techniques; field test data; location estimate; noisy environments; nondestructive testing; partial discharge propagation model; partial discharge sites; power cables; waveform match; Digital signal processing; Instruments; Packaging; Partial discharges; Power cables; Pulse measurements; Stress; Time measurement; Voltage; Working environment noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1994., Conference Record of the 1994 IEEE International Symposium on
  • Conference_Location
    Pittsburgh, PA
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-1942-7
  • Type

    conf

  • DOI
    10.1109/ELINSL.1994.401458
  • Filename
    401458