Abstract :
It is well known that water-tree is one of the main reasons of XLPE cable insulation aging. With the widespread use of XLPE cables, how to diagnose water-tree aging in insulation becomes more and more important. It has been found that a small DC component will be produced through the insulation of XLPE cables in service. By detection of this DC component, the degree of the cable insulation degradation can be examined, and hot-line diagnosis is realized as well. In this paper, according to a possible model of DC component production, research work of simulating hot-line diagnosis has been conducted with 10 kV XLPE cables in the laboratory. The experimental results indicate that the DC component is in good correspondence with the degradation caused by water trees
Keywords :
XLPE insulation; ageing; insulation testing; life testing; power cable insulation; power cable testing; trees (electrical); 10 kV; DC component method; DC component production; cable insulation aging; hot-line XLPE cable diagnosis; insulation degradation; water-tree; Aging; Cable insulation; Cables; Conductors; Copper; Degradation; Laboratories; Leakage current; Production; Trees - insulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 1994., Conference Record of the 1994 IEEE International Symposium on
Conference_Location :
Pittsburgh, PA
ISSN :
1089-084X
Print_ISBN :
0-7803-1942-7
Type :
conf
DOI :
10.1109/ELINSL.1994.401459
Filename :
401459
Link To Document :
بازگشت